What was found
CORROSION FWD CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT BS 500A+6 TO 500A+18; BS 500B+2 TO BS 500B+18; BS 500C+10 TO BS 500C+14 RBL 25 ; / [01] UPDATED MEASUREMENT TABLE; [02] EVALUATED CORROSION AT ALL LOCATIONS FOUND DEEPEST LOCATION TO BE AT BS 500A+6 FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-10-2 USING DIAL DEPTH GAUGE ATS 2678 S/N UNKNOWN; [03] VERIFIED EVALUATED CORROSION AT ALL LOCATIONS FOUND DEEPEST LOCATION TO BE AT BS 500A+6 FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.; [04] CORRECTION TO STEP 2 SHOULD BE SRM 53-00-53-1A-2; [05] FABRICATED NEW FCB RH FLOOR TO SIDEWALL SUPPORT BS 500A-500D; IAW SRM 51-40-05-0G-0; SRM 53-30-53-01-2; DWG 143A7500. APPLIED CHEMICAL CONVERSION COATING IAW SRM; 51-20-01-0G-0. MATERIAL; BAC1496-444#7075T62; LOT# 1475361-1; AND OK TO PRIME.; [06] VERIFIED FABRICATED NEW FCB RH FLOOR TO SIDEWALL SUPPORT BS 500A-500D; IAW SRM 51-40-05-0G-0; SRM 53-30-53-01-2; DWG 143A7500. APPLIED CHEMICAL CONVERSION COATING IAW SRM; 51-20-01-0G-0. MATERIAL; BAC1496-444#7075T62; LOT# 1475361-1.<BR>VERIFIED OK TO PRIME.; [07] PRIMED NEW FCB RH FLOOR TO SIDEWALL SUPPORT; BS 500A-500D; IAW SRM 51-21-01-0G-0.; [08] VERIFIED CORRECTIVE ACTION 7