What was found
CORROSION FWD CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT BS 480+6; +18; BS 500+10; +14; BS 500A+6; +10; +14; +18; BS 500B+10; BS 500C+10 LBL25 ; / [01] UPDATED MEASUREMENT TABLE; [02] EVALUATED CORROSION AT ALL LOCATIONS FOUND DEEPEST LOCATION TO BE AT BS 480+6 LBL25 WL 156. FOUND 0.015 REMOVED FROM ORIG 0.040 IN A 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS 2678 S/N UNKNOWN; [03] VERIFIED EVALUATED CORROSION AT ALL LOCATIONS FOUND DEEPEST LOCATION TO BE AT BS 480+6 LBL25 WL 156. FOUND 0.015 REMOVED FROM ORIG 0.040 IN A 1'X1' AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.; [04] LOCATED AND DRILLED NEW FCB LH FLOOR TO SIDEWALL SUPPORT; BS 396-500D; LBL 25; IAW SRM 51-40-05-0G-0; DWG143A7500; [05] VERIFIED CORRECTIVE ACTION 4.<BR><BR>PART TO BE INSTALLED ON TTG8Q0049MSU