What was found
CORROSION FWD CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT BS 400+10; +18 RBL 25 ; / [01] EVALUATED CORROSION BS400+10 AND +18 FOUND DEEPEST LOCATION TO BE BS400+10 RBL 25 WL 156 0.015 IN A 1'X1' AREA REMOVED FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 1225 S/N UNKNOWN; [02] VERIFIED OUT OF LIMITS PER SRM 53-00-53-1A-2; [03] FABRICATED NEW FCB RH FLOOR TO SIDEWALL SUPPORT; BS396-420; IAW SRM 51-40-05-0G-0; SRM 53-30-53-01-2; DWG 143A7500. APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01-0G-0. MATERIAL; BAC1496-444#7075T62; LOT#1419983-2. AND OK TO PRIME.; [04] VERIFIED FABRICATED NEW FCB RH FLOOR TO SIDEWALL SUPPORT; BS396-420; IAW SRM 51-40-05-0G-0; SRM 53-30-53-01-2; DWG 143A7500. APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01-0G-0. MATERIAL; BAC1496-444#7075T62; LOT#1419983-2.<BR>VERIFIED OK TO PRIME.; [05] PRIMED NEW RH FLOOR TO SIDEWALL SUPPORT; BS 396-420; RBL 25 IAW SRM 51-20-01-0G-0.; [06] VERIFIED CORRECTIVE ACTION 5