What was found
CORROSION FWD CARGO COMPARTMENT AFT SHIELD BS 500+6; +10; +14 RBL 25 ; / [01] UPDATED MEASUREMENT TABLE; [02] EVALUATED SHIELD; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] VERIFIED EVALUATED SHIELD; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0.; [04] LOCATED AND DRILLED FWD CARGO BAY AFT DOOR SHIELD AT RBL 25 BS 500+6; BS 500+10; BS 500+14 IAW SRM 51-40-05-0G-0 AND DWG 143A0080; [05] VERIFIED STEP 4 COMPLETE; [06] LOCATED AND DRILLED FWD CARGO BAY AFT DOOR SHIELD AT RBL 25 BS 480-BS 500A IAW SRM 51-40-05-0G-0 AND DWG 143A0080.