What was found
CORROSION FWD CARGO COMPARTMENT FWD SHIELD BS 420+2; +6; RBL 25 ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMIT IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMIT IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0.; [03] LOCATED AND DRILLED NEW FWD CARGO BAY FWD DOOR SHIELD AT RBL 25 BS 420+2; BS 420+6 IAW SRM 51-40-05-0G-0 AND DWG 143A0080; [04] VERIFIED STEP 3 COMPLETE; [05] LOCATED AND DRILLED NEW FWD CARGO BAY FWD DOOR SHIELD AT RBL 25 BS 420-BS 440 IAW SRM 51-40-05-0G-0 AND DWG 143A0080.