As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON AFT CARGO BAY FLOOR T STRAP BS 887 LBL 6 TO RBL 6 WL 168 ; / [01] EVALUATED CORROSION ON FLOOR STRAP; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION #1; [03] RECEIVED NEW FLOOR T STRAP ON PO# 846049 LOCATED AND DRILLED ALL PER SRM 51-40-05-0G-0; DWG 146A7500 AND 147A7500; [04] VERIFIED CORRECTIVE ACTION 3