What was found
***CORROSION*** AFT CARGO; L/H FLOOR TO SIDEWALL SUPPORT CORRODED BS 727I TO 78O LBL25 / REMOVED CORROSION L/H FLOOR SIDEWALL SUPPORT IAW SRM 51-10-02-0G-0; FOUND TO BE OUT OF LIMITS AT 100% IAW SRM 53-00-53-1A-2; REMOVED DAMAGED AREA OF SIDEWALL SUPPORT BS 727I TO 780 LBL25 PER SRM 53-00-53-2R-5; AND SRM 51-40-02-0G-0; FABRICATED REPAIR PARTS IAW SRM 53-00-53-2R-5; TREATED & PRIMED REPAIR PARTS IAW AMM-51-21-41-370-802 & 51-21-72-370-804; INSTALLED REPAIR PARTS IAW SRM 53-00-53-2R-5 & SRM 51-40-02-0G-0; USING MAT BAC1496-377 LOT# 5051578