What was found
SUPPLEMENTAL INFORMATION: KEEL BEAM PANEL 192F SHOWS CORROSION ON FLAME SPRAY AT ANTENNA LOCATIONS. / IDENTIFIED PART MATERIAL PER SRM 51-70-14-0G-0; FIG 1; TABLE 2. DETERMINED DAMAGE TO BE BEYOND LIMITS PER SRM 51-70-14-1A-0; PARA; 4C. APPLICABLITY OF SRM 51-70-14-2R-1; PARA 2G AND SRM 51-70-14-2R-4; PARA 5. DAMAGE REMOVED PER SRM 51-70-14-2R-4; PARA 5A-D. FABRICATED FOIL MESH REPAIR PLIES PER SRM 51-70-14-2R-4 PARA 5D TABLE 202. INSTALLED FOIL MESH PLIES PER SRM 51-70-14-2R-4 PARA 5E&I&5 TABLE 203. PREAPRED; PRIMED; AND PAINTED PANEL 192F IAW SRM 51-70-14-2R-4; STEP 5.J.13-14.