As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO PIT DOORWAY LOWER SILL STRUCTURE UPPER STRAP STA 784 - 817 RBL 20 HAS CORROSION ON UPPER SURFACE / REMOVED CORROSION FROM AFT CARGO PIT DOORWAY LOWER SILL UPPER STRAP. ORG THICKNESS 0.100;MATERIAL LOSS IS .012 OUT OF SRM 53-60-15-1A-1 ALLOWABLE LIMIT.REMOVED UPPER STRAP FROM STA 775 TO 861 AND INSTALLED NEW STRAP IAW SRM 51-40-02 AND DWG 146A8120 REV A SHEET 10.