What was found
AFT CARGO PIT DOORWAY LOWER SILL WEB STA 794 - 827 HAS CORROSION ON UPPER SURFACE / BLENDED OUT CORROSION ON AFT CARGO LOWER SILL WEB IAW B737-700 SRM 51-10-02-0G-0. ORIGINAL THICKNESS 0.045'; MATERIAL LOSS 0.020'; THE AREA FOUND TO BE OUT OF LIMIT IAW B737-SRM 53-60-15-1A-1. LOCATED AND DRILLED NEW WEB IAW B737-700 SRM 51-40-05 INSTALLED THE WEB IAW B737-700 SRM 51-40-02 AND DWG 146A8340 REV A. APPLIED CIC THE NEW INSTALLED WEB IAW B737-700 AMM 51-21-91-620-802.