What was found
***CORROSION*** AFT CARGO BAY FLOOR PANEL SPLICE PLATE AT BS 887 HAS AREAS OF CORROSION BETWEEN LBL 9 AND RBL 21. / LOCATED AND DRILLED NEW SPLICE PLATE ON ACT AT B.S 887 PER SRM 51-40-02-0G-0 AND SRM 51-40-05-0G-0 AND DWG 146A9401 P/N 7530863 OK TO INSTALL 56179R 5DEC17 INSP 385 12-5-17 INSTALLED NEW SPLICE PLATE ON ACB AT B.S. 887 PER SRM 51-40-02-0G-0