What was found
CRACKED LOWER R/H COMPOSITE BULKHEAD AT BS663 RBL34 WL158. DAMAGE FOUND ON LOWER R/H COMPOSITE BULKHEAD. FOUND TO BE OUT OF LIMITS IAW SRM 57-10-10-1A-2 STEP 4.D.(1). WILL BE REPAIRED BY REPLACEMENTS IAW SRM 51-10-02-0G-0; PAR. 9.C.;12] INSTALLED NEW RT VAPOR BARRIER COMPOSITE BULKHEAD IAW SRM 51-40-02-0G-0 AND DWG 111A1001 REV. B. AND DWG 111A1000 REV. B. INSTALLED NEW RT VAPOR BARRIER COMPOSITE BULKHEAD IAW SRM 51-40-02-0G-0 AND DWG#111A1001 REV. B. AND DWG#111A1000 REV. B.