What was found
CORROSION FWD CARGO FLOOR TO SIDEWALL SUPPORT BS 400+6+10, 420+10, 440+6, 500+2, 500B+18, 500C+10, LBL 25. REMOVED CORROSION ON TO SIDEWALL SUPPORT, FOUND TO BE OUT OF LIMITS AT BS.400+6 L=1.800' W=0.700' D=0.013' ORIGINAL THICKNESS 0.040' REMAINING MAT 0.027' IAW SRM 53-00-53-1A-2, FIG 103, DETAIL C. LOCATE, DRILLED AND APPLIED CHIMICAL CONVERSION COATING ON NEW FLOOR SIDEWALL SUPPORT BS 400 TO 500D IAW SRM 51-20-01-0G-0 & SRM 51-40-05-0G-0. FABRICATED NEW FLOOR TO SIDEWALL SECTION BS 400-500D LBL 25 & SPLICE AT BS 490 AND APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-40-05, SRM 51-20-01, & SRM 53-00-53-2R-6.