What was found
FAIRING 195CL RADIUS IS CRACKED AT AFT EDGE. DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-40-70-1A-1 TABLE 101, PARA 4.B. REPAIR TO BE ACCOMPLISHED IAW SRM 51-70-05 PER SRM 53-40-70-2R-1 PARA 4.B(2) AND 4.D(1); TABLE 202. VALIDATED REPAIR PER SRM 51-70-05-2R-6. VISUALLY EXAMINED EXTENT OF DAMAGE; TAP TESTED - DISBOND NOTED, AND REMOVED .4' X .6' OF DAMAGE AT CRACK LOCATION. PREPPED & CLEANED REPAIR AREA IAW SRM 51-70-05-2R-6 PARA 4.A-C. FABRICATED REPAIR PLIES. INSTALLED REPAIR PLIES VACUUM BAGGED AND SET FOR CURE IAW SRM 51-70-05-2R-6 PARA 4.E-G. REPAIRED IAW SRM 51-70-05-2R-6.