What was found
FWD CARGO STRINGER 25R, BS 500 - 500A SHIELD UPPER SURFACE CORRODED. REMOVED CORROSION IAW SRM 51-10-02-0G-0; [02] VERIFIED 1.; [03] PERFORMED UT THICKNESS INSP ON FWD CARGO COMPT R/H STR 25 BETWEEN STA 500 AND 500A SHIELD UPPER SURFACE. IAW B 737 NDT PART 4 51-00-00 PROCE 3. TOOL 27MG. BC 172139. CALIB DUE 4-1-22. MINNI THICK 0.020'.; [04] ORIGINAL MAT. 0.032' MAT. REMOVED 0.020' MAT. REMAINING 0.012' FOUND OUT OF LIMITS IAW SRM 53-30-15-1A-1 FIG 103. PG 27. NEW SHIELD. INSTALLATION WILL BE ACCOMPLISHED ON CARD 5330-E-16461-NG.