What was found
AFT CARGO FLOOR AREA BS 907 RT RAIL HAS CORROSION AT NET ATTACH FITTING. REMOVED CORROSION IAW SRM 51-10-02-0G-0. PERFORMED UT THICKNESS INSP ON REWORKED AREA IAW NDT P4 51-00-00 PROC.3, PERFORMED EVALUATION WITH UT THICKNESS AT REWORKED AREA AND ADJACENT STRUCTURE. IAW NDT PART 4 51-00-00 PROCE 3. MIN THICK 0.048'. ORIGINAL MATERIAL THICKNESS 0.070'. FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. FIG. 103; DETAIL G.; [06] ADDING TO STEP 1. REMOVED RT TRACK -NET ATTACH FITTING IAW SRM 51-40-02-0G-0. REPLACEMENT OF RT TRACK-NET ATTACH FITTING WILL BE ACCOMPLISH ON TASK TTG8Q00A4AA4.