As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO FLOOR AREA BETWEEN BS 927 - 947.5 RT RAIL CORRODED. REMOVED CORROSION IAW SRM 51-10-02-0G-0. PERFORMED UT THICKNESS INSP ON REWORKED AREA IAW NDT P4 51-00-00 PROC.3. ORIGINAL MATERIAL THICKNESS 0.070'; MATERIAL LOSS 0.011'; REMAINING MATERIAL 0.059'. FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. FIG. 103; DETAIL G. REPLACED IAW SRM 51-40-02-0G-0 AND DRAWING 147A7500.