***CORROSION*** FLOOR TO SIDE WALL SUPPORT STA500C+11 - 500H+7; LBL24; WL155 / LOOR TO SIDEWALL SUPPORT AT STA. 500C + 11' TO 500H + 7'; LBL 24 FOUNT TO BE OUT OF LIMITS IAW SRM 53-30-51-1A-1; FIG 103; DETAIL 'A'. REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-OG-0. FABRICATED; TREATED; AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AND REPAIR PARTS IAW SRM 51-40-02-OG-0; SRM 53-00-53-2R-5; AMM 51-00-58-201; AMM 51-21-72-370-804; AND DWG 143A7501. INSTALLED DISPLACED STRUCTURE IAW SRM 51-40-02-OG-0 AND DWG 248A0603.