What was found
A22-43; AFT PIT STA 727G+11-757; LBL21; WL153; Z-CHANNEL; CORROSION ADJACENT TO SEVERAL FASTENER HOLES ON UPPER SURFACE AND 4EA ON LOWER SURFACE; MRK'D. ; / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15; [02] EVALUATED ALLOWABLE LIMITS; .040 ORIGINAL 'T' .026 REMAINING .024 LOSS FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 TOOL USED #AAR 36649 DUE 12/08/22; [03] VERIFIED STEP 1; [04] VERIFIED STEP 2; [05] VERIFIED ITEMS 1 THROUGH 4<BR>OUT OF LIMITS; [06] REMOVED DAMAGE SECTION : CUT OUT BETWEEN STA 727G- 727F AND 787-807 IAW SRM 53-00-53-2R-5; [07] VERIFIED ITEM 6; [08] VERIFIED MATERIAL ID REPAIR PARTS IS BAC1496-377 7075-T6 TAG#A108167 IAW SRM 53-00-53-2R-5 REPAIR 5; [09] VERIFIED ITEM 8; [10] VERIFIED STEPS 8 & 9; [11] FABRICATED Z ANGLE REPAIR PARTS IAW SRM 53-00-53-2R-5 REPAIR 5; [12] VERIFIED STEP 11 IS COMPLETE; [13] VERIFIED ITEMS 11 AND 12<BR>OK TO TREAT AND PRIME