What was found
FORWARD CABIN FLOOR PANEL 222AF HAS A DELAMINATION ON THE UPPER SKIN AT AFT O/B CORNER ; / DAMAGE WAS FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.; REMOVED ALL DAMAGED SKIN AND LOOSE PIECES OF CORE; CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 3A-F.<BR>OK TO POT EXPOSED CORE.; [04] ADDITION TO CORRECTIVE ACTION 3: REMOVED 7EA THROUGH INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B; [05] VERIFIED CORRECTIVE ACTION ITEMS 1 - 4.<BR><BR>VERIFIED SRM 53-00-50-2R-1 IS APPLICABLE.<BR><BR>OK TO POT EXPOSED CORE.; [06] APPLIED POTTING BMS 5-28TY19 LOT#AK1FP5844K IAW SRM 53-00-50-2R-1 PARA 3G.; [07] CURED POTTING; SANDED SMOOTH TO SURFACE AND CLEANED.<BR>FABRICATED REPAIR PLIES USING BMS 9-3H2 LOT#1458851-1<BR>OK TO INSTALL IAW SRM 53-00-50-2R-1 PARA 3H-K.<BR>USED THERMOMETER ID:PER2220 S/N:UNKNOWN; [08] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 6 AND 7. OKAY TO INSTALL REPAIR PLIES PER SRM 53-00-50-2R-1.; [09] INSTALLED REPAIR PLIES USING BMS 8-201TY4 LOT#1459268-4; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2583 S/N:5432766772 <BR>IAW SRM 53-00-50-2R-1 PARA 3K-L.;CURED REPAIR PLIES IAW SRM 53-00-50-2R-1 PARA 3M.<BR>USED THERMOMETER ID:PER2220 S/N:UNKNOWN; [12] UNBAGGED AND TRIMMED EXCESS MATERIAL IAW SRM 53-00-50-2R-1 PARA 3M.; [13] INSTALLED PREVIOUSLY REMOVED INSERTS USING BMS 5-107 LOT#AK0DP4051K IAW SRM 53-00-50-2R-1 PARA 3N.<BR>USED THERMOMETER ID:PER2220 S/N:UNKNOWN;