What was found
***CORROSION*** AFT CARGO BAY FLOOR SPLICE AT BS 727D +6 CORRODED / UPON INVESTIGATION AFT GARBO BAY FLOOR SPLICE; TEE STRAP AT BS 727D+6; FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE ON SRM. PART WILL BE REPAIR BY REPLACEMENT. IAW SRM 51-10-02-0G-0. FABRICATED NEW TEE STRAP; ITEM# BAC1505-100581#7075T6; LOT# 1294347 APPLIED CHEMICAL CONVERSION AND PRIMER. IAW DWG# 146A9401; SOPM 20-43-03 AND AMM 51-21-72-370-804. 80002U 07FEB18.