What was found
***CORROSION*** FORWARD CARGO R/H FLOOR TO SIDEWALL SUPPORT BS 500C+8 TO 500H+17. / REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT ANGLE IN FWD CARGO COMPARTMENT AT STA. 500C + 8' TO 500 H + 17' IAW SRM 51-10-02-OG-0 L 1.70' X W .900' X D .012' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REPAIRED FLOOR TO SIDEWALL SUPPORT ANGLE IAW SRM 53-00-53-2R-5. TREATED REPAIR PARTS IAW AMM 51-21-41-370-801 PRIMED REPAIR PARTS IAW AMM 51-21-72-370-801 SPLICE LOCATION IS AT STA. 500D + 10'