As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ACB; FLOOR PANEL 140BF; WARP AND DISFIGURED. / LOCATED AND DRILLED / COUNTER SINK PANEL #140BF FROM 0.071 2024-T3 LOT # 1332197-1; APPLIED CHEMICAL COATING; PER SRM 51-40-05-0G-0; SRM 51-40-08-0G-0; PER AMM 51-21-41-370-801; AMM 51-21-72-370-804 AND DRAWING 453A2610. 1035C 04APR18 INSP 379 04APR18 APPLIED PRIMER TO FLOOR PANEL PER AMM 51-21-72-370-804.