What was found
***CORROSION*** ON FORWARD CARGO BAY DOOR CUTOUT SUB THRESHOLD WEB BS 440-492; RBL 22-30; WL 156 / FOUND TO BE OUT OF LIMITS DUE TO CORROSION PROXIMITY TO FASTENER HOLES SRM 53-30-15-1A-1. REMOVED FCB SUB THRESHOLD WEB BS 440-492 PER SRM 51-40-02. RECIEVED NEW WEB SI # 7530597; LOCATED DRILLED; INSTALLED NUT PLATES; INSTALLED PER SRM 51-40-02-0G-0; DWG # 143A8330.