What was found
SUPPLEMENTAL INFORMATION: ***CORROSION*** AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT R/H FROM STA 727H TO STA 767 AROUND FASTENER HOLES. / REMOVED CORROSION FROM R/H FLOOR TO SIDEWALL SUPPORT FASTENER HOLES AT STA 727H TO 767 IAW SRM 51-16-02-0G-0; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED R/H SIDWALL SUPPORT IAW SRM 51-40-02-0G-0. FABRICATED & INSTALLED NEW FLOOR TO SIDEWALL SUPPORT FROM ITEM BAC 1496-377; P.O. #673062 IAW SRM 51-40-02-0G-0 & SRM 53-00-53-2R-5 AND BOEING