What was found
*CORROSION* (AFT CARGO) CORROSION AROUND FASTENER HOLES ON L-ANGLE ON LOWER MAIN SILL R/H BETWEEN STA. 767 AND 790 RBL 21.0 / REMOVED AREAS 2EA AREA 1 IS 2.35'L X .90'W AREA 2 IS 2.30'L X .90W BOTH FROM AROUND FASTENER HOLES BOTH FOUND OUT OF LIMITS IAW SRM 51-10-02-0G-0 STEP 9-C LOCATED AND DRILLED NEW 'L' ANGLE P.O.# 7560094-04 P/N# 146A8123U20 I.A.W. SRM 51-40-02-0G-0 AND DRAWING # 146A8125 INSTALLED NEW 'L' ANGLE IAW SRM 51-40-02-0G-0 AND DRAWING # 146A8125 80644U 13MAR18