What was found
AFT PASSENGER COMPARTMENT FLOOR STRUCTURE: R-2 DOOR CUTOUT: 'Z' ANGLE HAS SURFACE CORROSION ON HORIZONTAL; VERTICAL; AND RADIUS SURFACES. STARTING AT STA 951 THROUGH STA 992. MARKED / REMOVED AND REPLACED Z ANGLE PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PASSENGER COMPARTMENT FLOOR STRUCTURE: R-2 DOOR CUTOUT: 'Z' ANGLE HAS SURFACE CORROSION ON HORIZONTAL; VERTICAL; AND RADIUS SURFACES. STARTING AT STA 951 THROUGH STA 992. MARKED / REMOVED AND REPLACED Z ANGLE PER SRM 51-40-02.