What was found
CRACK STRINGER 26L LOCATED BS540 AT FWD CARGO COMPARTMENT ; 2021-585105 / [01] ULTRASONIC THICKNESS GAGE P/N:45MG; S/N: 130060401; DUE DATE: 22-APR-22.; [07] PERFORMED PERMANENT REPAIR LOCATED ON STRINGER 26L LOCATED BS540 AT FWD CARGO COMPARTMENT IAW SRM <BR>B737-700 53-00-03-2R-1 REPAIR 1. MATERIAL USED: STRINGER SECTION P/N: 7075-T0 0.045 P.O: 2021-162754 ANGLES AND CHANNEL P/N: 7075-T0 0.050 P.O: 2021 139514 SEE INDIVIDUAL STEP BELOW RII CERTIFIED