As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT STA 887 FLOOR TRANSITION STRIP CORRODED / NO CORROSION LIMITS PUBLISHED IN SRM FOR STA 887 FLOOR TRANSITION STRIP. THEREFORE PART IS OUT OF LIMITS. REMOVED OUT OF LIMITS FLOOR TRANSITION STRIP AT STA 887 AND INSTALLED NEW FLOOR TRNSITION STRIP RT NO: 146A9401U39 ATG: WN6233 IAW SRM 51-40-02-0G-0 AND DWG: 146A7500 REV C. ATAG: WN6233