What was found
FWD CARGO COMPARTMENT R/H Z-ANGLE STA 500E PLUS 10 TO STA 500H HAS CORROSION AS MARKED. / FWD CARGO RH 'Z' ANGLE STA 500E+10 TO 500H HAS CORROSION BLENDED CORROSION AND FOUND BLENDS AT 500E+10 TO BE OUT OF LIMITS ORIG .040' REMOVED .005' REMAINING .035' IAW SRM 53-00-53-1A-2 BLENDS FROM 500F-500H FOUND TO BE IN LIMITS ORIG .040' REMOVED .003' REMAINING .037' IAW SRM 53-00-53-1A-2 REMOVED AND REPLACED 'Z' ANGLE FROM 500A 500E+10 IAW SRM 51-40-02-0G-0 AND IAW SRM 53-00-53-2R-5