What was found
CORROSION ON RAIL AT AFT CARGO BAY BS767+6 LBL8. MARKED. / [01] EVALUATED CORROSION ON RAIL BS 767+6 LBL 8 WL 156; FOUND 0.020 REMOVED FROM ORIG 0.063 IN 1'X1' AREA; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER ID 4566A;[02] VERIFIED CORRECTIVE ACTIONS STEP 1.;[03] TRIMMED OUT DAMAGE ON RAIL BS 767+6 LBL 8 WL 156 IAW SRM 53-00-53-2R-2 STEP 4(D);[04] REQUEST HFEC ON TRIM EDGE FOR CRACK FREE CONDITION;[05] VERIFIED DAMAGE REMOVAL PER SRM 53-00-53-2R-2.;[06] VERIFIED APPLICABILITY IAW SRM 53-00-53-2R-2 AND SRM 53-00-53-1A-2;[07] VERIFIED APPLICABILITY OF SRM 53-00-53-2R-2 AND SRM 53-00-53-1A-2;[08] HFEC INSPECTED CUTOUT AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23; NO CRACKS NOTED DURING TIME OF INSPECTION.<BR>EQUIP ID#: IS000450 S/N: N500D000M120071;[09] LOCATED AND DRILLED REPAIR ANGLE; MADE FROM BAC1510-1355#7050-T76511 SI#7530199 IAW SRM 53-00-53-2R-2 OK TO INSTALL;[10] VERIFIED LOCATE AND DRILL OF NEW ANGLE; REQUIRES CHEMICAL CONVERSION AND PRIME OF BARE METAL AREAS; BEFORE OK TO INSTALL; PER SRM 53-00-53-2R-2.;[11] APPLIED A CHEMICAL CONVERSION COATING TO THE BARE SURFACES IAW SRM 51-20-01 AND PRIMED THE BARE SURFACES IAW SOPM 20-41-02;[12] OK TO INSTALL REPAIR ANGLE;[13] VERIFIED CORRECTIVE ACTION 12.<BR>OK TO INSTALL;[14] INSTALLED REPAIR ANGLE ON RAIL AT AFT CARGO BAY BS 767+6 LBL 8 WL 156 IAW SRM 53-00-53-2R-2 AND SRM 51-40-02-0G-0;[15] RII INSPECTION COMPLETE;[16] INSPECTION COMPLETE