What was found
FWD CARGO BAY GUSSET IS CRACKED AT BS 500D COMMON TO STR19R WL 192 / [01] UPDATED MEASUREMENT TABLE;[02] LOCATED AND DRILLED NEW FWD CARGO BAY GUSSET AT BS 500D STR 19R WL 192 IAW DWG 143A7902 AND SRM 51-40-05-0G-0 OK TO INSTALL;[03] PRIOR TO LOCATE AND DRILL; REMOVED GUSSET AT BS500D STR19R WL192 IAW SRM 51-40-02-0G-0;[04] VERIFIED CORRECTIVE ACTIONS 1-3.<BR>OK TO INSTALL;[05] INSTALLED NEW FWD CARGO BAY GUSSET AT BS 500D STR 19R WL 192 IAW DWG 143A7902 AND SRM 51-40-02-0G-0;[06] VERIFIED CORRECTIVE ACTION STEP 5.;[07] VERIFIED COMPLETE