As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO COMPARTMENT BETWEEN STA 927 AND 947.5 AND BETWEEN STR 26R AND 25R FLOOR TRACK IS CORRODED TOP SURFACE AROUND 5 EA FASTENER NUT PLATE HOLES / REMOVED AND EVALUATED CORROSION. ORIGINAL THICKNESS .073' LOSS OF .012' WITH .061' REMAINING. BLEND FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED AND REPLACED -14 CARGO TRACK STA 947 TO FACTORY SPLICE AT STA 887 PER DWG 147A501 REV B AND SRM 51-40-02-0G-0