What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS867 LBL9. / [01] ENTERED MEASUREMENTS;[02] REMOVED CORROSION IAW SRM 51-10-02. AREA MEASURES 1.00' X 0.300' X 0.003'. ORIGINAL THICKNESS:0.090'. REMAINING MATERIAL: 0.087';[03] VERIFIED CORRECTIVE ACTION 2;[04] EDIT ITEM 2. <BR>MICROMETER ID: ATS1671; SN 65093024; CAL DUE 10/2022;[05] HFEC INSPECTED BLEND AREA PER NDTM PT6 51-00-00 PROCEDURE 23; NO CRACKS NOTED; EQUIP ID ATS729;[06] UT INSPECTED BLEND AREA PER NDTM PT4 51-00-00 PROCEDURE 2; LOWEST READING WAS .087'; EQUIP ID ATS2342;[07] CORROSION REMOVAL ON AFT BULKHEAD FLOOR TO SUPPORT BS 867 LBL 9 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM;[08] VERIFIED CORRECTIVE ACTION 7;[09] AFT CARGO BAY- AFT BULKHEAD VACUUM WASTE TANK ENCLOSURE SUPPORT ANGLE REPAIRED PER ER# 22-153-00340 REV:A. <BR><BR>TASKCARD COMPLETED.;[10] COMPLETED MEASUREMENT PARAMETERS #15.;[11] VERIFIED CORRECTIVE ACTION #9 AND #10;[12] VERIFIED TASK COMPLETE