What was found
***CORROSION*** FWD LEFT HAND ENTRY DOOR MOP SILL FWD HARD POINT HAS CORROSION / FWD LEFT HAND ENTRY DOOR MOP SILL FWD HARD POINT FOUND TO BE OUT OF LIMITS DUE NO ALLOWABLE DAMAGE IN SRM. REMOVED AND REPLACED HARD POINT P/N 141A5220 -2 IAW SRM 51-40-02-0G-0 AND DWG 141A5220