What was found
FWD CARGO COMPARTMENT FLOOR STRUCTURE STA 500B+10 TO 500I R\H Z-ANGLE HAS CORROSION. / FWD CARGO R/H Z ANGLE 500B+10 HAS CORROSION. ORIG IS .040 LOSS IS .020 REMAINING IS .020 AT LOWEST POINT I/A/W SRM 53-00-53-1A-2 FIG 103. REMOVED OLD Z-ANGLE; LOCATED; DRILLED; TRIMMED I/A/W SRM 51-40-02-0G-0 ALSO SRM 53-00-53-2R-5 REPAIR 5 ALSO BOEING DWG 143A7500 REV - . TREATED PRIMED I/A/W AMM 51-21-41-370-803 AMM 51-21-72-370-801. INSTALLED I/A/W SRM 53-00-53--2R-5 REPAIR 5. APPLIED C.I.C I/A/W AMM 51-21-91-620-802 SPLICE INSTALLED BETWEEN BS 500E AND 500F.