What was found
CRACKED STRINGER AT AREA AFT OF FCB BS536 S-26R WL153. ACCOMPLISHED EWIS PROTECTION WITHIN THE REPAIR AREA AT BS 536 S-26R WL153 IAW AMM 20-60-07-913-801. FABRICATED, LOCATED, AND DRILLED HAT SECTION SPLICE IAW SRM 53-00-03-2R-1 REPAIR 1. LOCATED AND DRILLED REPLACEMENT SECTION AND APPLIED CHEMICAL CONVERSION COATING IAW SRM 53-00-03-2R-1 REPAIR 1. FABRICATED, LOCATED, AND DRILLED HAT SECTION SPLICE FROM EXTRUSION IAW SRM 53-00-03-2R-1 REPAIR 1. LOCATED AND DRILLED REPLACEMENT SECTION AND APPLIED CHEMICAL CONVERSION COATING IAW SRM 53-00-03-2R-1 REPAIR 1. INSTALLED REPAIR PARTS IAW SRM 53-00-03-2R-1; REPAIR 1.