What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS 500A - 500D RBL23. EVALUATED FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY MEASURES= L= 1'; W=600'; D= 0.011'; ORIGINAL MATERIAL THICKNESS=0.040'; MATERIAL LOSS=0.011'; REMAINING THICKNESS=0.029'. SIDEWALL SUPPORT IS OUT OF LIMITS. IAW SRM 53-00-53-1A-2, ALLOWABLE DAMAGE 2; STEP 4.A(2)(A). REMOVED FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY IAW SRM 51-40-02-0G-0. FABRICATED FLOOR TO SIDEWALL SUPPORT. LOCATED, DRILLED, & APPLIED A CHEMICAL CONVERSION COATING IAW SRM 51-40-05 SRM 53-30-53-0I-2 & SRM 51-20-01. APPLIED PRIMER TO THE FLOOR TO SIDEWALL SUPPORT IAW SOPM 20-44-04. INSTALLED FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02; DWG 143A7500.