What was found
***CORROSION*** IN FWD ANCHOR HOLE ON ACB FLOOR SUPPORT INBOARD OF SHIELD STA 847+2 IN RBL 14 / REMOVED CORROSION ON CARGO TIE DOWN TRACK AT BS 847+2 RBL 14 PER SRM 51-10-02-0G-0. DAMAGE MEASURES 1.0' X 1.0' WITH 100% MATERIAL LOSS. DAMAGE IS OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED CARGO TRACK FROM BS 727+4-887 PER SRM 51-40-02-0G-0. FABRICATED TRACK SPLICE AT BS 747-10 FROM BAC1509-100688 7050-T6511 LOT# 1297327 PER SRM 53-00-53-2R-3 INSTALLED REPLACEMENT TRACK AT RBL 14 FROM BS 727+4 - BS 887 PER SRM 51-40-02-0G-0 AND DWG # 146A7500 SHEET 42