What was found
FWD CARGO PIT L/H FLOOR CAP STRIP HAS CORROSION AS MARKED. / NO ALLOWABLE LIMITS REPLACED L/H FLR CAP STRIP P/N 453A1611-16 AS REQUIRED IAW BOEING DWG 453A1611 REV: B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO PIT L/H FLOOR CAP STRIP HAS CORROSION AS MARKED. / NO ALLOWABLE LIMITS REPLACED L/H FLR CAP STRIP P/N 453A1611-16 AS REQUIRED IAW BOEING DWG 453A1611 REV: B.