What was found
FOUND CORROSION ON BOTTOM OF NUT PLATE STRIP UNDER THE AFT CARGO FLOOR STRUCTURE FROM STA 787-793 RBL 25. / REMOVED AND REPLACED STRIP PER SRM 51-40-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON BOTTOM OF NUT PLATE STRIP UNDER THE AFT CARGO FLOOR STRUCTURE FROM STA 787-793 RBL 25. / REMOVED AND REPLACED STRIP PER SRM 51-40-02