What was found
***CORROSION*** ON FWD ENTRY AFT HARD-POINT STA 344 LBL 54 WL 208 / REMOVED FWD ENTRY AFT HARD-POINT STA 344 LBL 54 WL 208 IAW SOPM 20-50-01. STRUCTURAL ITEM HAS NO APPLICABLE REPAIR PROCEDURES IN SRM. HARD-POINT IS REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9 83802U 11OCT18 LEAD 122 11OCT18 INSP 24 13OCT18 REPLACED FWD ENTRY AFT HARD-POINT BS 344 LBL 54 WL 208 PER REF B737 AMM 20-50-11-910-801 AND IPC 53-42-00-29. 92962U 13-OCT-18 LEAD 138 13OCT18