What was found
FWD. ENTRY DOOR CUT OUT SURROUND STRUCTURE; STA 312 +3 TO STA 328 +9 ; S17L SCUFF PLATE SUPPORT ANGLE HAS CORROSION. / FOUND CORROSION ON SCUFF PLACE SUPPORT ANGLE AT STA 312 + 3 TO STA 328 + 9 S17L TO BE OUT OF LIMITS DUE TO DAMAGE FASTENER HOLES IAW SRM 53-10-15-1A-1 FIG 108 D. REMOVED DAMAGE ANGLE IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW ANGLE MPN 141A8112-2 IAW SRM 51-40-05-0G-0 AND BOEING DWG 141A6720. INSTALLED NEW SUPPORT ANGLE IAW SRM 51-40-02-0G-0 AND BOEING DWG 141A8110