What was found
***CORROSION*** ON EXTERNAL SKIN UNDER VERTICAL STAB 1013-1093 BETWEEN STR 3L-3R / CORROSION WAS FOUND ON EXTERNAL SKIN STA. 1016-1088; STR. 3L-3R IN AREA OF 78.0'L X 30.0'W X .005'D FOUND IN LIMITS PER SRM 53-00-01-1A-1; FIG. 103; DET. C+D. AREA @ STA. 1030-1041 STR. 2L-2R EXCEEDS .10' AROUND EXISTING DOUBLER. NO DAMAGE PERMITTED PER SRM 53-00-01-1A-1 FIG 103 DET. IV. REPAIRED SKIN @ STA. 1016-1088 PER ER# 18-06120 REV IR AND EA# 1-753-33912 REV IR