What was found
AFT CARGO FLOOR STRUCTURE BS 927 - 947 INBD OF STR 27L INTERCOSTAL HAS CORROSION. REMOVED, EVALUATED DAMAGE. BLENDED CORROSION .046' ORIGINAL THICKNESS; REMOVED .010'; REMAINING .036' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-04-1A-1. REMOVED INTERCOSTAL WEB FROM AFT CARGO IAW SRM 51-40-02. TRIMMED TO SIZE; LOCATED &DRILLED NEW INTERCOSTAL WEB IAW SRM 51-40-05 & DWG# 147A7580 REV E. TREATED AND PRIMED NEW INTERCOSTAL IAW AMM 51-21-72-370-804 AND AMM 51-21-41-370-803. INSTALLED NEW INTERCOSTAL WEB AFT CARGO STA 927-947 STR 27L IAW SRM 51-40-02 AND BOEING DWG 147A7580 REV B.