What was found
FORWARD PASSENGER COMPARTMENT FLOOR STRUCTURE; S17L AT FWD. ENTRY DOOR CUT OUT ANGLE ATTACHED TO SKIN HAS CORROSION. / REMOVED CORROSION I-A-W SRM 51-10-02-0G-0. L=2'; W=1'; D=.009' OUT OF LIMITS PER SRM 53-10-15-1A-1 PG 4.C.(2)(A). REMOVED FWD ENTRY DOOR CUT OUT ANGLE PER SRM 51-40-02-0G-0. FORMED NEW ANGLE PER B DWG# 141A8234 SRM 51-30-01; MATERIAL USED 2024 'O'.063' LOT# 5019863; HEAT TREATED 2024T3 PO# 721212; LOCATED AND DRILLED FASTENER HOLES PER SRM 51-40-05-0G-0. TREATED AND PRIMED PER AMM 51-21-41-370; AMM 51-21-72-370. INSTALLED ANGLE PER BDWG# 141A8230 AND SRM 51-40-02-0G-0. AT FWD PASSENGER COMPT FLOOR STRUCTURE S17L FWD ENTRY DOOR CUTOUT.