As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND CHAFING ON S-27R TO FRAME GUSSET AT BS420 RBL6. MARKED / GUSSET AT STA. 420 RBL 6 OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN SRM. REPAIRABLE BY REPLACEMENT PER SRM 51-10-02-0G-0; FABRICATED GUSSET OUT OF BAC 1493-856 7075T62 LOT #1249633 PER DWG. 143A1010. INSTALLED GUSSET PER SRM 51-40-02-0G-0 AND DWG. 143A8130. 91195U 12-28-18