What was found
CRACK FOUND, LT HORIZONTAL STAB LOWER SKIN HSS 193.90; 16' FROM FWD SPAR AT I/B ROW OF FASTENERS. CRACK LENGTH: 1.125'. STRIPPED PAINT ON STAB IAW AMM 51-21-11-150-810; REMOVED FASTENERS IAW SRM 51-40-02-0G-0; PERFORMED CUTOUT OF DAMAGE IAW SRM 55-10-01-2R-11 & 51-10-02-0G-0; PERFORMED HFEC INSP ON CUT OUT AREA IAW NDT PART 6 51-00-00 PROCE 23. NO CRACKS FOUND.; PERFORMED HFEC ROTO INSP ON OPEN HOLES . IAW NDT PART 6 51-00-00 PROCE 16. NO CRACKS FOUND.; PERFPORMED HFEC COUNTERSUNK INSP ON OPEN HOLES . IAW NDT PART 6 53-30-00 PROCE 3. NO CRACKS FOUND.; LOCATED & DRILLED DOUBLER & SKIN IAW SRM 51-40-05-0G-0 AND 55-10-01-2R-11 REPAIR 11; COUNTERSUNK DOUBLER IAW SRM 55-10-01-2R-11 REPAIR 11 & 51-40-08-0G-0.