What was found
CRACK FOUND, RT HORIONTAL STAB HSS 193.90; I/B ROW;16" FROM FWD SPAR. LENGTH OF CRACK 1'. STRIPPED PAINT ON LOWER SKIN IAW AMM 51-21-11-150-810; REMOVED FASTENERS IAW SRM 51-40-02-0G-0. PERFORMED CUTOUT OF DAMAGE IAW SRM 55-10-01-2R-11 & 51-10-02-0G-0. PERFORMED HFEC COUNTERSUNK INSP ON FASTENER OPEN HOLES IAW NDT PART 6 53-30-00 PROCE 3. NO CRACKS FOUND. LOCATED & DRILLED DOUBLER & SKIN IAW SRM 51-40-05-0G-0 & 55-10-01-2R-11 REPAIR 11. COUNTERSUNK FASTENER HOLES IAW SRM 55-10-01-2R-11 REPAIR 11 & SRM 51-40-08-0G-0. TREATED & PRIMED DOUBLER & SKIN IAW SOPM 20-44-04 AND 20-43-03. INSTALLED REPAIR IAW SRM 51-40-02-0G-0 & SRM 55-10-01-2R-11 REPAIR 11.