What was found
AFT CARGO EQUIPMENT BAY INNER STRUCTURE STA 996 BETWEEN STR 24L AND 25L AT WATER DRAIN HAS SIGNS OF CORROSION. / EVALUATED CORROSION FOUND TO BE OUT OF LIMITS DUE TO NO PUBLISHED SRM LIMITS. REMOVED AND REPLACED -18 FITTING PER SRM 51-40-02-0G-0 AND DWG 147A7443 REV B